These calculators use these formulas to determine the percent timer setting to achieve a specified application depth or completion time.
Where:
= The new pivot percent timer setting to achieve desired depth (as a %)
= The pivot percent timer setting to achieve known application depth (as a %)
= Known application depth (in)
= Desired new application depth (in)
Where:
= The new pivot percent timer setting to achieve desired completion time (as a %)
= The pivot percent timer setting to at known completion time (as a %)
= Known completion time (hrs)
= Desired completion time (hrs)
Where:
= The new pivot percent setting to achieve desired depth (as a %)
= Pivot full rotation time at 100% (hrs)
= Pivot full rotation time to apply 1 inch (hrs)
= Desired application depth (in)
Reference: Washington State University